Standard Specifications and Details
The City of Minot's Standard Specifications and Details for Construction provide contractors, developers, engineers, and the public in general with information regarding the requirements for infrastructure construction within the City of Minot.
Click here for the combined version: City of Minot Standard Specifications and Details for Construction - Revised 2021.
Click here for a Summary of Revisions.
Please contact us with any questions or concerns regarding these documents at engineers@minotnd.org or 701-857-4100.
Standard Specifications
Section | Description | Current Version | 2019 Version | Previous Version |
---|---|---|---|---|
100 | Information for Bidders | EJCDC | EJCDC | 2013 |
100 | Work Within Public Right of Way | 2021 | 2019 | new section |
200 | General Conditions | EJCDC | EJCDC | 2013 |
300 | Special Conditions | eliminated | eliminated | 2013 |
600 | Project Testing Requirements | in Section 1000 | in Section 1000 | 2013 |
800 | Price and Payment Procedures | in each Section & EJCDC | in each Section & EJCDC | 2013 |
900 | Submittal Procedures | in each Section & EJCDC | in each Section & EJCDC | 2013 |
1000 | Quality Requirements | 2021 | 2013 | |
1100 | Mobilization, Temporary Facilities and Controls | 2021 | 2019 | 2013 |
1200 | Temporary Erosion and Sediment Control | 2021 | 2019 | 2013 |
1300 | Product Requirements | EJCDC | EJCDC | 2013 |
1400 | Operation and Maintenance Manuals | 2021 | 2019 | 2013 |
1500 | Removals | 2021 | 2019 | 2013 |
1600 | Project Site Clearing | 2021 | 2019 | 2013 |
1700 | Adjustment of Structures | 2021 | 2019 | 2013 |
1800 | Excavation and Embankment | 2021 | 2019 | 2013 |
1900 | Subgrade Preparation | 2021 | 2019 | 2013 |
2000 | Trench Excavation and Backfill | 2021 | 2019 | 2013 |
2100 | Water Main | 2021 | 2019 | 2013 |
2200 | Water Services | 2021 | 2019 | 2013 |
2300 | Sanitary Sewer | 2021 | 2019 | 2013 |
2310 | Bypass Pumping | 2021 | 2019 | new section |
2400 | Sanitary Services | 2021 | 2019 | 2013 |
2700 | Storm Sewer | 2021 | 2019 | 2013 |
2800 | Subsurface Drainage | 2021 | 2019 | 2013 |
2900 | Aggregate Base Course | 2021 | 2019 | 2013 |
2910 | Cement Stabilized Base | 2021 | 2019 | new section |
3000 | Hot Mix Asphalt Pavement | 2021 | 2019 | 2013 |
3010 | Bituminous Pavement Maintenance and Repair | 2021 | 2019 | new section |
3100 | Portland Cement Concrete Pavement | 2021 | 2019 | 2013 |
3110 | Concrete Pavement Maintenance and Repair | 2021 | 2019 | new section |
3200 | Concrete Curb and Gutter | 2021 | 2019 | 2013 |
3300 | Concrete Walks, Medians, and Driveways | 2021 | 2019 | 2013 |
3400 | Post Mounted Traffic Signs | 2021 | 2019 | 2013 |
3500 | Pavement Markings | 2021 | 2019 | 2013 |
3600 | Street Lighting | 2021 | 2019 | 2013 |
3700 | Lawns and Grasses | 2021 | 2019 | 2013 |
3800 | Traffic Signals | 2021 | 2019 | new section |
4000 | Lift Stations | 2021 | 2019 | 2013 |
2021 Standard Details
Erosion Control
- ERO-1_SILT FENCE MACHINE SLICED
- ERO-2_SILT FENCE SUPPORTED
- ERO-3_SILT FENCE STANDARD
- ERO-4_SILT FENCE J-HOOK
- ERO-5_CONSTRUCTION ENTRANCE ROCK AND WOODCHIPS
- ERO-6_SLOPE TRACKING
- ERO-7_CONCRETE WASHOUT
- ERO-8_INLET PROTECTION TURF AREA DRAINS
- ERO-9_DITCH CHECK MACHINE SLICED SILT FENCE
- ERO-10_EROSION CHECKS BALED HAY OR STRAW
- ERO-11_EROSION CHECKS FIBER ROLLS
- ERO-12_EROSION CONTROL BLANKET INSTALLATION
- ERO-13_FLOATING SILT CURTAIN
Bedding
Water
- WAT-1_HYDRANT
- WAT-2_HYDRANT DETAIL WITH VERTICAL BEND
- WAT-3_GATE VALVE AND BOX INSTALLATION
- WAT-4_BUTTERFLY VALVE AND BOX INSTALLATION
- WAT-5_WATERMAIN WET TAP
- WAT-6A_METER PIT UP TO 4IN
- WAT-6B_METER PIT 6 TO 8IN
- WAT-7_CONCRETE THRUST BLOCKING
- WAT-8_WATER MAIN OFFSET
- WAT-9_RESTRAINT DEVICE FOR PVC PIPE BELL JOINTS
Sanitary
Lift Station
Services
Storm
- STO-1_STORM SEWER MANHOLE
- STO-2_STORM SEWER JUNCTION MANHOLE
- STO-3_CATCH BASIN CURB and GUTTER INSTALLATION
- STO-4_ROUND INLET TURF INSTALLATION
- STO-5_CATCH BASIN MANHOLE CURB AND GUTTER INSTALLATION
- STO-6_CATCH BASIN MANHOLE TURF INSTALLATION
- STO-7_DOUBLE CATCH BASIN CURB AND GUTTER INSTALLATION
- STO-8_INLET-SLOTTED DRAIN
- STO-9_DRAIN TILE
- STO-10_FLARED END SECTION AND TRASH RACK
- STO-11_STABILIZED OUTFALL
- STO-12_F.E.S. CUTOFF WALL
- STO-13_PIPE JOINT REPAIR BAND
Street
- STR-1_CASTING STRUCTURE ADJUSTMENT
- STR-2A_CURB AND GUTTER
- STR-2B_KNOCK DOWN CURB AND GUTTER
- STR-3_MOUNTABLE CURB and GUTTER TRANSITION
- STR-4_MOUNTABLE CURB and GUTTER AT CATCH BASINS
- STR-5_TYPE I CURB AND GUTTER AT CATCHBASINS
- STR-6_VALLEY GUTTER
- STR-7_SIDEWALKS AND PATHWAYS
- STR-8_PEDESTRIAN CURB RAMP PATHWAY-SIDEWALK
- STR-9_PEDESTRIAN CURB RAMP GENERAL LOCATION
- STR-10_DRIVEWAY PLACEMENT
- STR-11A_CONCRETE DRIVEWAY APRON BOULEVARD 0 TO 1.5FT
- STR-11B_CONCRETE DRIVEWAY APRON BOULEVARD 1.5FT TO 4FT
- STR-11C_CONCRETE DRIVEWAY APRON BOULEVARD GREATER THAN 4 FT
- STR-12_TYPICAL UTILITY PLACEMENT
- STR-13_TYPICAL INFRASTRUCTURE PLACEMENT
- STR-14_TYPICAL PUBLIC STREET SECTION RESIDENTIAL
- STR-15_TYPICAL CUL-DE-SAC RESIDENTIAL
- STR-16_FLOATING MANHOLE CASTING
- STR-17A_CONCRETE PAVEMENT REPAIR TRANSVERSE JOINT REPLACEMENT
- STR-17B_CONCRETE PAVEMENT REPAIR FULL PANEL REPLACEMENT
- STR-17C_CONCRETE PAVEMENT REPAIR
- STR-17D_CONCRETE PAVEMENT SAW CUT AND SEALANT
Traffic
- TRA-1_WORK ZONE ADA COMPLIANT TEMP PED BARRICADES
- TRA-2_ROAD CLOSED TYPE III BARRICADES
- TRA-3A_TRAFFIC SIGNAL STANDARD FOUNDATION SELECTION TABLE
- TRA-3B_TRAFFIC SIGNAL FOUNDATION 30,36,42 INCH DIA
- TRA-3C_TRAFFIC SIGNAL FOUNDATION 24 INCH DIA
- TRA-4A_SIGNAL STANDARDS
- TRA-4B_SIGNAL STANDARD WITH MAST ARM TYPE IV and COMBINATION
- TRA-4C_SIGNAL MAST ARM HEAD MOUNTING
- TRA-4D_SIGNAL POLE HEAD MOUNTING
- TRA-5A_EMERGENCY VEHICLE PRE-EMPTION
- TRA-5B_SIGNAL STANDARD BASE ANCHORING AND TERMINAL BLOCK
- TRA-5C_MAST ARM MOUNTED SIGNS
- TRA-6A_PEDESTRIAN PUSH BUTTON POST AT BASE
- TRA-6B_PEDESTRIAN PUSH BUTTON POST MOUNTING
- TRA-7A_TYPE V PEDESTRIAN FLASHER FOUNDATION
- TRA-7B_TYPE V PEDESTRIAN FLASHER
- TRA-8A_SOLAR SCHOOL ZONE FLASHER
- TRA-8B_SOLAR SCHOOL ZONE FLASHER FOUNDATION
- TRA-9A_FIBER OPTIC DETAIL
- TRA-9B_FIBER OPTIC DETAIL
- TRA-10_STREET SIGNS
- TRA-11_TYPICAL SIGN INSTALLATION LATERAL LOCATIONS
- TRA-12_TYPICAL SIGN INSTALLATION AT INTERSECTIONS
- TRA-13_TYPE A POLE
- TRA-14_TYPE A POLE BASE
- TRA-15_PULL BOX IN GRASS BOULEVARD
- TRA-16_PULL BOX IN CONCRETE
- TRA-17_FEEDPOINT ENCLOSURE
- TRA-18_FEED POINT WIRING
- TRA-19_UNDERGROUND CABLE STREET LIGHTING
2019 Standard Details
Erosion Control
- ERO-1_SILT FENCE STANDARD
- ERO-2_SILT FENCE SUPPORTED
- ERO-3_SILT FENCE MACHINE SLICED
- ERO-4_SILT FENCE J-HOOK
- ERO-5_CONSTRUCTION ENTRANCE ROCK AND WOODCHIPS
- ERO-6_SLOPE TRACKING
- ERO-7_CONCRETE WASHOUT
- ERO-8_INLET PROTECTION TURF AREA DRAINS
- ERO-9_DITCH CHECK MACHINE SLICED SILT FENCE
- ERO-10_EROSION CHECKS BALED HAY OR STRAW
- ERO-11_EROSION CHECKS FIBER ROLLS
- ERO-12_EROSION CONTROL BLANKET INSTALLATION
- ERO-13_FLOATING SILT CURTAIN
Bedding
Water
- WAT-1_HYDRANT DETAIL
- WAT-2_HYDRANT DETAIL WITH VERTICAL BEND
- WAT-3_GATE VALVE AND BOX INSTALLATION
- WAT-4_BUTTERFLY VALVE AND BOX INSTALLATION
- WAT-5_WATER MAIN WET TAP
- WAT-6A_UP TO 4 INCH METER PIT
- WAT-6B_6-8 INCH METER PIT
- WAT-7_CONCRETE THRUST BLOCKING
- WAT-8_WATER MAIN OFFSET
- WAT-9_WATER SERVICE FOR REPLACEMENT PROJECTS
- WAT-10_RESTRAINT DEVICE FOR PVC PIPE BELL JOINTS
Sanitary
Lift Station
Services
Storm
- STO-1_STORM SEWER MANHOLE
- STO-2_STORM SEWER JUNCTION MANHOLE
- STO-3_CATCH BASIN CURB and GUTTER INSTALLATION
- STO-4_ROUND INLET TURF INSTALLATION
- STO-5_MANHOLE CURB AND GUTTER INSTALLATION DETAIL
- STO-6_MANHOLE TURF INSTALLATION
- STO-7_DOUBLE CATCH BASIN DETAIL
- STO-8_INLET-SLOTTED DRAIN
- STO-9_PVC PERFORATED PIPE
- STO-10_FLARED END SECTION AND TRASH RACK
- STO-11_F.E.S. CUTOFF WALL AND STABLIZED OUTFALL
- STO-12_F.E.S. CUTOFF WALL
- STO-13_PIPE JOINT REPAIR BAND
Street
- STR-1_CASTING STRUCTURE ADJUSTMENT
- STR-2_CURB AND GUTTER
- STR-3_MOUNTABLE CURB and GUTTER TRANSITION
- STR-4_MOUNTABLE CURB and GUTTER CONSTRUCTION AT CATCH BASIN
- STR-5_TYPE I CURB AND GUTTER CONST AT CB
- STR-6_CONCRETE VALLEY GUTTER
- STR-7_SIDEWALKS AND PATHWAYS
- STR-8_PEDESTRIAN CURB RAMP PATHWAY-SIDEWALK
- STR-9_PEDESTRIAN CURB RAMP GENERAL LOCATION
- STR-10_DRIVEWAY PLACEMENT
- STR-11A_CONCRETE DRIVEWAY APRON BOULEVARD 0 TO 1.5FT
- STR-11B_CONCRETE DRIVEWAY APRON BOULEVARD 1.5FT TO 4FT
- STR-11C_CONCRETE DRIVEWAY APRON BOULEVARDGREATER THAN 4 FT
- STR-12_TYPICAL UTILITY PLACEMENT
- STR-13_TYPICAL INFRASTRUCTURE PLACEMENT
- STR-14_TYPICAL PUBLIC STREET SECTION-RESIDENTIAL
- STR-15_TYPICAL CUL-DE-SAC SECTION-RESIDENTIAL
- STR-16_FLOATING MANHOLE CASTING DETAIL
- STR-17A_CONCRETE PAVEMENT REPAIR TRANSVERSE JOINT REPLACEMENT
- STR-17B_CONCRETE PAVEMENT REPAIR FULL PANEL REPLACEMENT
- STR-17C_CONCRETE PAVEMENT REPAIR
- STR-17D_CONCRETE PAVEMENT SAW CUT AND SEALANT
Traffic
- TRA-1_WORK ZONE ADA COMPLIANT TEMP PED BARRICADES
- TRA-2_ROAD CLOSED TYPE III BARRICADES
- TRA-3A_TRAFFIC SIGNAL STANDARD FOUNDATION SELECTION TABLE
- TRA-3B_TRAFFIC SIGNAL FOUNDATION 30,36,42 INCH DIA
- TRA-3C_TRAFFIC SIGNAL FOUNDATION 24 INCH DIA
- TRA-4A_SIGNAL STANDARDS
- TRA-4B_SIGNAL STANDARD WITH MAST ARM TYPE IV and COMBINATION
- TRA-4C_SIGNAL MAST ARM HEAD MOUNTING
- TRA-4D_SIGNAL POLE HEAD MOUNTING
- TRA-5A_EMERGENCY VEHICLE PRE-EMPTION
- TRA-5B_SIGNAL STANDARD BASE ANCHORING AND TERMINAL BLOCK
- TRA-5C_MAST ARM MOUNTED SIGNS
- TRA-6A_PEDESTRIAN PUSH BUTTON POST AT BASE
- TRA-6B_PEDESTRIAN PUSH BUTTON POST MOUNTING
- TRA-7A_TYPE 'V' PEDESTRIAN FLASHER FOUNDATION
- TRA-7B_TYPE 'V' PEDESTRIAN FLASHER
- TRA-8A_SOLAR SCHOOL ZONE FLASHER
- TRA-8B_SOLAR SCHOOL ZONE FLASHER FOUNDATION
- TRA-9A_FIBER OPTIC DETAIL
- TRA-9B_FIBER OPTIC DETAIL
- TRA-10_STREET SIGNS
- TRA-11_TYPICAL SIGN INSTALLATION LATERAL LOCATIONS
- TRA-12_TYPICAL SIGN INSTALLATION AT INTERSECTIONS
- TRA-13_TYPE A POLE
- TRA-14_TYPE A POLE BASE
- TRA-15_PULL BOX IN GRASS BOULEVARD
- TRA-16_PULL BOX IN CONCRETE
- TRA-17_FEEDPOINT ENCLOSURE
- TRA-18_FEED POINT WIRING
- TRA-19_UNDERGROUND CABLE STREET LIGHTING